Digital twin

A live electrical model of your network, built for decisions.

KIGG's digital twin joins your single-line diagram, protection settings, test results and live measurements in one physics-based model. It keeps every asset's health and risk current, and lets engineers test a decision before they make it in the field.

Digital twin layers: physical assets feed live data, which feeds the model and decisions (illustrative)PHYSICALASSETSLIVEDATAMODEL &DECISIONS81345176ILLUSTRATIVE

What it does

Four things a spreadsheet and a SCADA screen cannot do together.

01

Network model

An as-built electrical model from HV intake to feeders, with load flow, short-circuit and protection coordination studies run on the same data.

IEC 60909 · IEEE 1584
02

Live condition

Measurements from your substation automation, online sensors and test campaign results, aligned to the asset they describe.

IEC 61850 · IEC 60870-5-104
03

Physics-gated anomaly detection

Alerts fire only when measurements break what the physics expects, such as a thermal model or a gas trend. Fewer false alarms, and each one comes with a probable cause.

IEC 60076-7 · IEC 60599
04

What-if and N-1

Contingency screening, outage planning and loading headroom, checked on the model before anyone switches anything in the field.

N-1 screening · reliability indices

Architecture

Built to sit inside a utility's OT network.

  • Deploys on-premise or in a private cloud, behind your OT DMZ
  • Open data model aligned with IEC 61968 and IEC 61970 CIM
  • Reads from IEC 61850 and IEC 60870-5-104 systems you already run
  • Pushes work recommendations to your EAM or CMMS
  • Every alert and score traceable to the measurement behind it

Where it is used

From 400 kV substations to the rack PDU.

Transmission substations

ICTs, breakers and instrument transformers at 400/220 kV and below, with health and risk kept current.

Traction substations

Single-phase traction transformers and feeders, where outage planning has to fit the timetable.

Industrial plants

Rectifier, furnace and distribution transformers, MV switchgear and HV motors under continuous duty.

Data centres

Capacity and contingency across the electrical chain, from HV intake to the rack PDU.

Part of a programme

The twin is how the picture stays current.

KIGG delivers the digital twin as part of the asset management programme, not as a standalone software licence. Between test campaigns, it is what keeps every health index, risk ranking and recommendation up to date.